Thermal Performance of an Aluminum/Ammonia Heat Pipe Under Reflux Mode
[摘要] During instrument-level or spacecraft-level ground testing, heat pipes may be placed in reflux mode, with condenser above evaporator. A liquid pool will form at the bottom of the heat pipe. If heat is applied to a site below the surface of the liquid pool in a vertical heat pipe, the heat pipe can work properly under reflux mode. A superheat is required for startup. If heat is applied to a site above the liquid pool, the heat pipe is not expected to work unless additional heat is applied to the liquid pool to provide the needed flow circulation. There are many reason to minimize the additional heater power. An experimental investigation was conducted to study the heat pipe behavior under this configuration.
[发布日期] 2019-03-26 [发布机构] 
[效力级别]  [学科分类] 力学,机械学
[关键词] GROUND TESTS;TEMPERATURE EFFECTS;HEAT PIPES;ALUMINUM;AMMONIA;INVESTIGATION [时效性] 
   浏览次数:25      统一登录查看全文      激活码登录查看全文