Measurements of Beam Momentum at the Stacking Energy of the Accumulator
[摘要] The momentum and orbit length of beam on the central and extraction orbits of the Antiproton Source Accumulator are calculated from measurements of revolution frequency and transverse beam position. This report gives the results of measurements made at the stacking energy before and after the 1998-99 Accumulator lattice upgrade. Before the lattice upgrade, the Accumulator central orbit length and momentum are measured to be: L{sub c} = 474.0433 {+-} 0.0025 m, p{sub c} = 8819.5 {+-} 4.1 MeV/c. After the lattice upgrade the central orbit length and momentum are measured to be: L{sub c} = 474.0532 {+-} 0.0016 m, p{sub c} = 8803.4 {+-} 2.7 MeV/c. The extraction orbit length and momentum prior to the lattice upgrade are measured to be: L{sub e} = 474.1916 {+-} 0.0054 m, p{sub e} = 8900.8 {+-} 9.2 MeV/c. After the lattice upgrade the extraction orbit length and momentum are measured to be: L{sub e} = 474.1599 {+-} 0.0036 m, p{sub e} = 8886.3 {+-} 6.1 MeV/c.
[发布日期] 2000-11-29 [发布机构] Fermi National Accelerator Laboratory
[效力级别] [学科分类]
[关键词] Beam Position;43 Particle Accelerators;Tanks Accelerators;Accelerators;Antiproton Sources [时效性]