Electromagnetic Borehole Flowmeter Testing in R-Area
[摘要] Six constant-rate, multiple-well aquifer tests were recently conducted in R-area to provide site-specific in situ hydraulic parameters for assessing groundwater flow and contaminant transport models of R-Reactor Seepage Basins (RRSB) plume migration and RRSB remedial alternatives. The pumping tests were performed in the Upper Three Runs and Gordon aquifers between December 1999 and February 2000. The tests provide reliable estimates of horizontal conductivity averaged over aquifer thickness, and a relatively large horizontal zone of influence. To complement these results, Electromagnetic Borehole Flowmeter (EBF) testing was subsequently performed to determine the vertical variation of horizontal conductivity for RPC-2PR, RPC-3PW, RPT-2PW, RPT-3PW, RPT-4PW and RPT-30PZ. The EBF data generally indicate significant aquifer heterogeneity over the tested screen intervals (Figures 14, 16-18, 20, 22, 24, 26 and 27-31). The vertical variation of groundwater flow in or out of the well screen under ambient conditions was also measured (Figures 13, 15, 19, 21, 23 and 25). These data have implications for contaminant monitoring.
[发布日期] 2000-10-12 [发布机构] Savannah River Site (S.C.)
[效力级别] [学科分类]
[关键词] Flowmeters;Pumping;Settling Ponds;Testing;Monitoring [时效性]