Ultrasonic evaluation of beryllium-copper diffusion bonds
[摘要] A study was performed to compare the effectiveness of several advanced ultrasonic techniques when used to determine the strength of diffusion bonded beryllium-copper, which heretofore have each been applied to only a few material systems. The use of integrated backscatter calculations, frequency domain reflection coefficients, and time-of-flight variance was compared in their ability to characterize the bond strength in a series of beryllium-copper diffusion bond samples having a wide variation in bond quality. Correlation of integrated backscatter calculations and time-of-flight variance with bond strength was good. Some correlation of the slope of the frequency based reflection coefficient was shown for medium and high strength bonds, while its Y-intercept showed moderate correlation for all bond strengths.
[发布日期] 2000-06-08 [发布机构] Kansas City Plant (U.S.)
[效力级别]  [学科分类] 
[关键词] Copper;Adhesion;Joints;36 Materials Science;Performance Testing [时效性] 