Solubility of hydrogen and deuterium in bcc uranium-titanium alloys
[摘要] For the body-centered-cubic uranium-titanium alloy system, hydrogen and deuterium solubility measurements have been made on 12 alloy specimens ranging in composition from pure uranium to pure titanium and over a temperature range of 900-1473 K. The results are described in closed form by an analytical model within a standard error of 3%. The Einstein temperature (1680 K), and thus the isotope effect, was independent of alloy composition. The solubility and the enthalpy of solution were strongly dependent on alloy composition, more so at low titanium concentrations.
[发布日期] 1997-05-20 [发布机构]
[效力级别] Proceedings Paper [学科分类]
[关键词] solubility;uranium-titanium alloys [时效性]