Effect of contact conditions on embrittlement of T91 steel by lead-bismuth
[摘要] The T91 martensitic steel is a candidate structural material for the liquid lead-bismuth eutectic (LBE) MEGAPIE spallation target. This paper first reviews some results on Liquid Metal Embrittlement (LME) of martensitic steels by liquid metals. It appears that LME of steels can occur provided a few criteria are fulfilled simultaneously. Intimate contact between liquid metal and solid metal is the first one. Usually, it is impossible to avoid the oxide film formation on the steel surface even after short exposure to air. This explains the difficulty arising when one would like to determine the susceptibility to LME of T91 steel whilst put into contact with lead-bismuth. Later, we report on different methods of surface preparation in order to remove the oxide layer on the T91 steel (PVD, soft soldering fluxes) and the resulting susceptibility to LME. (C) 2004 Elsevier B.V. All rights reserved.
[发布日期] 2004-11-01 [发布机构]
[效力级别] Proceedings Paper [学科分类]
[关键词] [时效性]