Response of NSTX liquid lithium divertor to high heat loads
[摘要] Samples of the NSTX Liquid Lithium Divertor (LLD) with and without an evaporative Li coating were directly exposed to a neutral beam ex-situ at a power of similar to 1.5 MW/m(2) for 1-3 s. Measurements of front face and bulk sample temperature were obtained. Predictions of temperature evolution were derived from a 1D heat flux model. No macroscopic damage occurred when the bare sample was exposed to the beam but microscopic changes to the surface were observed. The Li-coated sample developed a lithium hydroxide (LiOH) coating, which did not change even when the front face temperature exceeded the pure Li melting point. These results are consistent with the lack of damage to the LLD surface and imply that heating alone may not expose pure liquid Li if the melting point of surface impurities is not exceeded. This suggests that flow and heat are needed for future PFCs requiring a liquid Li surface. (C) 2013 Elsevier B.V. All rights reserved.
[发布日期] 2013-07-01 [发布机构]
[效力级别] Proceedings Paper [学科分类]
[关键词] [时效性]