Dynamic finite element analysis of third size charpy specimens of V-4Cr-4Ti
[摘要] A 2-D finite element analysis (FEA) of precracked, one-third-scale CVN specimens of V-4Cr-4Ti was performed to investigate the sensitivity of model results to key material parameters such as yield strength, failure strain and work hardening characteristics. Calculations were carried out at temperatures of -196 degrees C and 50 degrees C. Dynamic FEAs were performed using ABAQUS/Explicit v5.4. Finite element results are compared to experimental Charpy results from the production-scale heat of V-4Cr-4Ti (Heat #832665) as a benchmark. Agreement between the finite element model and the experimental data was very good at -196 degrees C, whereas at 50 degrees C the model predicted an absorbed energy slightly below the experimental value. (C) 1998 Elsevier Science B.V. All rights reserved.
[发布日期] 1998-10-01 [发布机构]
[效力级别] Proceedings Paper [学科分类]
[关键词] [时效性]