已收录 268921 条政策
 政策提纲
  • 暂无提纲
Evaluation of a field-deployable Nafion™-based air-drying system for collecting whole air samples and its application to stable isotope measurements of CO 2
[摘要] Atmospheric flask samples are either collected at atmospheric pressure by opening a valve of a pre-evacuated flask or pressurized with the help of a pump to a few bar above ambient pressure. Under humid conditions, there is a risk that water vapor in the sample leads to condensation on the walls of the flask, notably at higher than ambient sampling pressures. Liquid water in sample flasks is known to affect the CO 2 mixing ratios and also alters the isotopic composition of oxygen ( 17 O and 18 O ) in CO 2 via isotopic equilibration. Hence, for accurate determination of CO 2 mole fractions and its stable isotopic composition, it is vital to dry the air samples to a sufficiently low dew point before they are pressurized in flasks to avoid condensation. Moreover, the drying system itself should not influence the mixing ratio and the isotopic composition of CO 2 or that of the other constituents under study. For the Airborne Stable Isotopes of Carbon from the Amazon (ASICA) project focusing on accurate measurements of CO 2 and its singly substituted stable isotopologues over the Amazon, an air-drying system capable of removing water vapor from air sampled at a dew point lower than −2   ∘ C, flow rates up to 12 L min −1 and without the need for electrical power was needed. Since to date no commercial air-drying device that meets these requirements has been available, we designed and built our own consumable-free, power-free and portable drying system based on multitube Nafion™ gas sample driers (Perma Pure, Lakewood, USA). The required dry purge air is provided by feeding the exhaust flow of the flask sampling system through a dry molecular sieve (type 3A) cartridge. In this study we describe the systematic evaluation of our Nafion™-based air sample dryer with emphasis on its performance concerning the measurements of atmospheric CO 2 mole fractions and the three singly substituted isotopologues of CO 2 ( 16 O 13 C 16 O , 16 O 12 C 17 O and 16 O 12 C 18 O ), as well as the trace gas species CH 4 , CO , N 2 O and SF 6 . Experimental results simulating extreme tropical conditions (saturated air at 33  ∘ C) indicated that the response of the air dryer is almost instantaneous and that approximately 85 L of air, containing up to 4 % water vapor, can be processed staying below a −2   ∘ C dew point temperature (at 275 kPa). We estimated that at least eight flasks can be sampled (at an overpressure of 275 kPa) with a water vapor content below −2   ∘ C dew point temperature during a typical flight sampling up to 5 km altitude over the Amazon, whereas the remaining samples would stay well below 5  ∘ C dew point temperature (at 275 kPa). The performance of the air dryer on measurements of CO 2 , CH 4 , CO , N 2 O , and SF 6 and the CO 2 isotopologues 16 O 13 C 16 O and 16 O 12 C 18 O was tested in the laboratory simulating real sampling conditions by compressing humidified air from a calibrated cylinder, after being dried by the air dryer, into sample flasks. We found that the mole fraction and the isotopic composition difference between the different test conditions (including the dryer) and the base condition (dry air, without dryer) remained well within or very close to, in the case of N 2 O , the World Meteorological Organization recommended compatibility goals for independent measurement programs, proving that the test condition induced no significant bias on the sample measurements.
[发布日期]  [发布机构] 
[效力级别]  [学科分类] 内科医学
[关键词]  [时效性] 
   浏览次数:1      统一登录查看全文      激活码登录查看全文