Delayed presentation of infected common iliac artery pseudoaneurysm caused by malpositioned pedicle screw after minimally invasive scoliosis surgery
[摘要] To report delayed onset common iliac artery perforation and infected pseudoaneurysm caused by malpositioned pedicle screw after minimally invasive scoliosis surgery (MISS). A 21-year-old female was referred to our hospital with a 1-week history of abrupt right-sided low back pain, lower abdominal pain, and fever with a history of MISS using cannulated pedicle screws 18 months earlier. Paravertebral arterial erosion with pseudoaneurysm and retroperitoneal and paraspinal abscess were suspected. We performed resection of the pseudoaneurysm, vascular repair of right common iliac artery by angioplasty with a bovine patch and removal of implant. At 6 months after the last surgery, she had no limitations or problems in her daily activities with no recurrence of low back pain, abdominal pain, or fever as well as without loss of deformity. Our case showed that misplaced pedicle screws can cause potentially fatal complications, such as infected pseudoaneurysm, even in the late postoperative period.
[发布日期]  [发布机构] 
[效力级别]  [学科分类] 
[关键词] Abscess;Common iliac artery;Fistula;Pseudoaneurysm;Malpositioned cannulated pedicle screw;Minimally invasive scoliosis surgery [时效性] 