Feature extraction of partial discharge in low-temperature composite insulation based on VMD-MSE-IF
[摘要] Low-temperature composite insulation is commonly applied in high-temperature superconducting apparatus while partial discharge (PD) is found to be an important indicator to reveal insulation statues. In order to extract feature parameters of PD signals more effectively, a method combined variational mode decomposition with multi-scale entropy and image feature is proposed. Based on the simulated test platform, original and noisy signals of three typical PD defects were obtained and decomposed. Accordingly, relative moments and grayscale co-occurrence matrix were employed for feature extraction by K-modal component diagram. Afterwards, new PD feature vectors were obtained by dimension reduction. Finally, effectiveness of different feature extraction methods was evaluated by pattern recognition based on support vector machine and K-nearest neighbour. Result shows that the proposed feature extraction method has a higher recognition rate by comparison and is robust in processing noisy signals.
[发布日期] [发布机构]
[效力级别] [学科分类] 数学(综合)
[关键词] feature extraction;pattern recognition [时效性]