已收录 268921 条政策
 政策提纲
  • 暂无提纲
Development of an Actuator for Ambient to Cryo Application
[摘要] During the qualification campaign of the NIRSpec Instrument Mechanism, the actuator could not achieve the expected life time which was extended during the development phase. The initial design could not be adapted to the requested number of revolutions during that phase. Consequently the actuator needed to be modified such that the function of the mechanism would not be endangered and thus the overall function of the NIRSpec instrument. The modification included the change of the overall actuator design - internal dimensions, tolerances, materials, lubrication and assembly process - while keeping the interface to the mechanism, mass, and function. The lessons learned from the inspection of the failed actuator have been implemented in order to ensure the development and qualification success. The initially available time for this activity was in the range of 6 months to meet the overall program schedule.
[发布日期] 2010-05-12 [发布机构] 
[效力级别]  [学科分类] 空间科学
[关键词]  [时效性] 
   浏览次数:2      统一登录查看全文      激活码登录查看全文