Evaluation of Lightning Incidence to Elements of a Complex Structure: A Monte Carlo Approach
[摘要] There are complex structures for which the installation and positioning of the lightning protection system (LPS) cannot be done using the lightning protection standard guidelines. As a result, there are some "unprotected" or "exposed" areas. In an effort to quantify the lightning threat to these areas, a Monte Carlo statistical tool has been developed. This statistical tool uses two random number generators: a uniform distribution to generate the origin of downward propagating leaders and a lognormal distribution to generate the corresponding returns stroke peak currents. Downward leaders propagate vertically downward and their striking distances are defined by the polarity and peak current. Following the electrogeometrical concept, we assume that the leader attaches to the closest object within its striking distance. The statistical analysis is run for N number of years with an assumed ground flash density and the output of the program is the probability of direct attachment to objects of interest with its corresponding peak current distribution.
[发布日期] 2008-11-16 [发布机构]
[效力级别] [学科分类] 电子与电气工程
[关键词] [时效性]