Orbit response matrix measurements for 10Hz global orbit feedback in RHIC
[摘要] The 10 Hz global orbit feedback system (gofb) was designed to correct the 10 Hz horizontal beam perturbations in both rings that are suspected to be caused by vibrations of the final focusing quadrupoles (triplets). The full system envisioned for Run-11 consists of 36 BPMs, corresponding to 2 per triplet in each of the 12 triplet locations and two in each of the 6 arcs, and 1 dipole corrector at each triplet location for a total of 12 correctors. Prototype testing was successfully carried out during RHIC Run-10 in store condition with 4 new dipole correctors (with independent power supplies) and 8 stripline beam position monitors (BPMs) per accelerator. An SVD-based algorithm was used to compute the applied corrections. For Run-10, the response matrix was provided by W. W. MacKay. The response matrix R relates corrector angles to beam displacements at BPMs.
[发布日期] 2010-10-01 [发布机构] 
[效力级别]  [学科分类] 核物理和高能物理
[关键词] ALGORITHMS;BEAM POSITION;DIPOLES;FEEDBACK;FOCUSING;MONITORS;POWER SUPPLIES;QUADRUPOLES;TESTING;TRIPLETS relativistic heavy ion collider [时效性] 