Wakefield Calculations for Radiation Stopper 1 (RST1)
[摘要] The main result of this note is that no wakefield mitigation is required for the Radiation Stopper (RST1) in the LCLS injector. The RST1 geometry is not symmetric in the vertical direction, and we derive a slight modification to the diffraction model wake for a cylindrically symmetric (2D) cavity that can be used for this problem. Performing a full 3D MAFIA calculation for the nominal 1 mm (rms) long bunch, we show that the modified diffraction model well describes the wakefields generated in RST1. The results imply an on-axis emittance growth of 0.0075%, well below the 0.5% tolerance threshold. To reach the 0.5% threshold the beam would need to be mis-steered by a large amount - 7 mm - from the axis. One reason that the effect is small is that the beta functions at the RST1 are small.
[发布日期] 2010-12-13 [发布机构] 
[效力级别]  [学科分类] 核物理和高能物理
[关键词] LIGHT SOURCES;FREE ELECTRON LASERS;LINEAR ACCELERATORS;ELECTRON BEAM INJECTION;ENERGY ABSORPTION;BEAM BUNCHING;BEAM EMITTANCE XFEL [时效性] 