The Sandia MEMS Passive Shock Sensor : dormancy and aging.
[摘要] This report presents the results of an aging experiment that was established in FY09 and completed in FY10 for the Sandia MEMS Passive Shock Sensor. A total of 37 packages were aged at different temperatures and times, and were then tested after aging to determine functionality. Aging temperatures were selected at 100 C and 150 C, with times ranging from as short as 100 hours to as long as 1 year to simulate a predicted aging of up to 20 years. In all of the tests and controls, 100% of the devices continued to function normally.
[发布日期] 2010-12-01 [发布机构] 
[效力级别]  [学科分类] 工程和技术(综合)
[关键词] AGING;SENSORS;SHOCK WAVES;PERFORMANCE TESTING;MICROELECTRONIC CIRCUITS [时效性] 