Integrated Data Analysis (IDCA) Program - PETN Class 4 Standard
[摘要] The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of PETN Class 4. The PETN was found to have: 1) an impact sensitivity (DH50) range of 6 to 12 cm, 2) a BAM friction sensitivity (F50) range 7 to 11 kg, TIL (0/10) of 3.7 to 7.2 kg, 3) a ABL friction sensitivity threshold of 5 or less psig at 8 fps, 4) an ABL ESD sensitivity threshold of 0.031 to 0.326 j/g, and 5) a thermal sensitivity of an endothermic feature with Tmin = ~ 141 ?��C, and a exothermic feature with a Tmax = ~205?��C.
[发布日期] 2012-08-01 [发布机构]
[效力级别] [学科分类] 化学(综合)
[关键词] small-scale safety testing;proficiency test;round-robin test;safety testing protocols;HME;RDX;potassium perchlorate;potassium chlorate;sugar;dodecane;PETN [时效性]