Final Report - DuraMelter 100 Tests to Support LAW Glass Formulation Correlation Development, VSL-06R6480-1, Rev. 0
[摘要] This report describes the results of work and testing specified by Test Specifications 24590-LAW-TSP-RT-04-004, Rev. 0, Test Plans VSL-05T5480-1, Rev. 0 and Text Exceptions 24590-LAW-TEF-RT-05-00002. The work and any associated testing followed established quality assurance requirements and was conducted as authorized. The descriptions provided in this test report are an accurate account of both the conduct of the work and the data collected. Results required by the Test Plan are reported. Also reported are any unusual or anomalous occurences that are different from the starting hypotheses. The test results and this report have been reviewed and verified.
[发布日期] 2013-12-03 [发布机构]
[效力级别] [学科分类] 核能源与工程
[关键词] [时效性]