Production Facility Prototype Blower Installation Report with 1000 Hr Test Results
[摘要] The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 ??A on each side of the target, 5.72 ??A total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was need for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is currently being installed at the LANL facility for target and component flow testing. This report describes this blower/motor/pressure vessel package and the status of the facility preparations.
[发布日期] 2016-09-23 [发布机构] 
[效力级别]  [学科分类] 核物理和高能物理
[关键词] Accelerator Design;Technology;and Operations [时效性] 