Development of 1 kW Stirling cryocooler using a linear compressor
[摘要] Cryogenic cooling systems for HTS electric power devices require a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed a dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of the fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has a gamma-type configuration. The piston and displacer are supported with a flexure spring. A slit-type heat exchanger is adopted for the cold and warm-end, and the generated heat is rejected by cooling water. In the cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. The developed cryocooler reaches 47.8 K within 23.4 min. with no-load. Heat load tests shows a cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP.
[发布日期]  [发布机构] Department of Extreme Energy Systems, KIMM, Daejeon; 305-343, Korea, Republic of^1
[效力级别] 物理学 [学科分类] 材料科学(综合)
[关键词] Cooling Capacity;Cooling performance;Cryogenic cooling system;Electrical performance;Linear compressors;Maintenance cycles;Phase difference;Stirling cryocoolers [时效性] 
   浏览次数:33      统一登录查看全文      激活码登录查看全文