已收录 268921 条政策
 政策提纲
  • 暂无提纲
Second stage cooling from a Cryomech PT415 cooler at second stage temperatures up to 300 K with cooling on the first-stage from 0 to 250 W
[摘要] The amount of cooling delivered to the second stage of a two stage cooler is dependent on the second stage temperature and the amount of refrigeration provided by the cooler first stage. The second stage cooling as a function of temperature for a Cryomech PT-415 cooler (1.5 W at 4.2 K with 42 W on the first stage) has been estimated by scaling similar data that was measured for a Cryomech PT-410 cooler (1.0 W at 4.2 K with 28 to 30 W on the first stage). In order to accurately calculate the cool-down time for a superconducting magnet using PT-415 K coolers one must know how much cooling can be delivered by the cooler second-stage as a function of the second-stage temperature and the added cooling delivered to the cooler first-stage. There are applications where PT415 coolers are used in the temperature range from 15 to 25 K to liquefy hydrogen or cool magnets fabricated from MgB2. This report describes the method for estimating the cooler performance for a PT415 cooler as well as the results of the measurements on several PT415 coolers.
[发布日期]  [发布机构] FRIB, Michigan State University, East Lansing; MI; 48824, United States^1;Lawrence Berkeley Laboratory, M/S0161, Berkeley; CA; 94720, United States^2;Cryomech Inc., 113 Falso Drive, Syracuse; NY; 13211, United States^3
[效力级别] 物理学 [学科分类] 材料科学(综合)
[关键词] Down time;Similar datum;Stage cooling;Temperature range;Two-stage coolers [时效性] 
   浏览次数:52      统一登录查看全文      激活码登录查看全文