Transient numerical investigation on cold plate based water cooling system for battery module with large lithium-ion pouch cells
[摘要] This investigation presented a transient numerical study on cooling performance of cold plate based water cooling system for battery module with large lithium-ion pouch cells. The study was conducted at heat generation rates of large pouch cells with 0.07 W/cm3, 0.05 W/cm3 and 0.03 W/cm3. The operating temperature of cooling water were considered as 15 °C, 25 °C and 35 °C. The operating mass flow rates of water were considered as 0.05 kg/s, 0.10 kg/s and 0.15 kg/s. k- turbulence model in ANSYS CFX was used to simulate the flow in the water channel. The average battery temperature, maximum battery temperature and temperature difference between maximum and minimum were considered as critical parameters for analysing the cooling performance of battery thermal management system (BTMS) with large sized lithium-ion pouch cells. The study reported that for 0.03 W/cm3, the present cooling model was sufficient and for battery modules with higher heat generation rates need optimized strategy to provide efficient cooling.
[发布日期] [发布机构] School of Mechanical Engineering, Dong-A University, 37 Nakdong-Daero 550, Saha-gu, Busan, Korea, Republic of^1;Ingram School of Engineering, Texas State University, San Marcos; TX; 78666, United States^2
[效力级别] 材料科学 [学科分类]
[关键词] Battery temperature;Battery thermal managements;Cooling performance;Heat generation rate;Numerical investigations;Operating temperature;Optimized strategies;Temperature differences [时效性]