Performance improvement of a large capacity GM cryocooler
[摘要] This paper presents the improvement of a large GM cryocooler, Cryomech model AL600, based on redesigning a cold head stem seal, regenerator, heat exchanger and displacer bumper as well as optimizing operating parameters. The no-load temperature is reduced from 26.6 K to 23.4 K. The cooling capacity is improved from 615 W to 701W at 80 K with a power input of 12.5 kW. It has the highest relative Carnot Efficiency at 15.4%. The vibration of AL600 is investigated experimentally. The new displacer bumper significantly reduces the vibration force on the room temperature flange by 82 % from 520 N to 93 N.
[发布日期] [发布机构] Cryomech Inc., 113 Falso Drive, Syracuse; NY; 13211, United States^1
[效力级别] 物理学 [学科分类] 材料科学(综合)
[关键词] Carnot efficiency;Cooling Capacity;Displacers;G-m cryocooler;Operating parameters;Performance improvements;Power input;Vibration forces [时效性]