Temperature field study of hot water circulation pump shaft system
[摘要] In the process of engineering application under the condition of hot water circulation pump, problems of stress concentration caused by the temperature rise may happen. In order to study the temperature field in bearing and electric motor chamber of the hot water circulation pump and optimize the structure, in present paper, the model of the shaft system is created through CREO. The model is analyzed by ANSYS workbench, in which the thermal boundary conditions are applied to calculate, which include the calorific values from the bearings, the thermal loss from electric motor and the temperature from the transporting medium. From the result, the finite element model can reflect the distribution of thermal field in hot water circulation pump. Further, the results show that the maximum temperature locates in the bearing chamber.The theoretical guidance for the electric motor heat dissipation design of the hot water circulation pump can be achieved.
[发布日期] [发布机构] National Research Center of Pumps, Jiangsu University, Zhenjiang, Jiangsu; 212013, China^1
[效力级别] 工业技术 [学科分类] 工业工程学
[关键词] Ansys workbenches;Engineering applications;Maximum temperature;Shaft system;Temperature rise;Thermal boundary conditions;Thermal field;Thermal loss [时效性]