Doses to medical workers operating in a PET/CT department after the use of new dynamic techniques.
[摘要] Since new radiopharmaceuticals are used like [18F]-fluoro-3'-deoxy-3'-L- fluorothymidine and 18F fluoromethylcholine, also new dynamic techniques of imaging are used, measurements concerning the doses to medical staff are needed. The aim of this study was to measure the effective whole body dose of the personnel and compare them with the oldest. Estimation of equivalent dose for all members of the staff was monitored with the use of TLDs badges and electronic dosimeters. The duration of the study was year 2011 (983 patients).Concerning the nurses, we measured 10% increase in the wholebody doses and that is due to the longer time they spent near the patient (dynamic protocol). For technologist we measure 15-21% increase for they come near the patient immediately after administration. We can observe that there is an increase of the doses for technologists and nurses the numbers are significantly lower than the recommended annual dose limit by Euratrom 97/43.
[发布日期]  [发布机构] Medical Physics Department, Hygeia SA, Athens, Greece^1;Medical Physics Laboratory, School of Medicine National, Kapodistrian University of Athens, Greece^2;PET/CT Department, Hygeia SA, Athens, Greece^3;Konstantinos Dalianis MSc, Hygeia Hospital, Erythrou Stavrou 4 and Kifissias P.O, Marousi, Athens; 15123, Greece^4
[效力级别] 医药卫生 [学科分类] 卫生学
[关键词] Annual dose;Dynamic techniques;Electronic dosimeter;Equivalent dose;Medical staffs;Whole-body dose [时效性] 