已收录 268918 条政策
 政策提纲
  • 暂无提纲
Analysis of Unanchored Liquid Storage Tanks under Seismic Loads
[摘要]

Because of cost, cylindrical, ground supported liquid storage tanks are often not fixed to their foundation, even in seismic areas. For such an unanchored tank made of steel, the weight of the cylindrical shell is mostly insufficient to prevent local uplift due to seismic overturning moments. Although, for properly designed connecting pipes, uplift itself is not a problem, it results in larger vertical compressive stresses in the tank wall at the base, opposite to where the uplift occurs. These compressive stresses have often caused buckling, even in earthquakes which did not cause much damage to other structures.

Various investigators have studied the behavior of unanchored tanks experimentally, but, due to the complexity of the problem, so far very little theoretical work has been done. Two methods of analysis for static lateral loads are presented: An approximate one in which the restraining action of the base plate is modeled by nonlinear Winkler springs, and a more comprehensive one in which the two dimensional nonlinear contact problem is solved by the finite difference energy method. The theoretical results are compared with existing experimental results and with the approach from current U.S. design standards. The theoretical peak compressive stresses are in good agreement with the experimental results, but in some cases exceed those calculated by the code method by more than 100%.

Finally, a new design concept, by which the tank wall is preuplifted all around its circumference by inserting a ring filler is described. It will be shown theoretically and experimentally that this preuplift method substantially improves the lateral load capacity.

[发布日期]  [发布机构] University:California Institute of Technology;Department:Engineering and Applied Science
[效力级别]  [学科分类] 
[关键词] Civil Engineering [时效性] 
   浏览次数:21      统一登录查看全文      激活码登录查看全文