Conceptual model and recharge area of geothermal system in Gede-Pangrango and Pancar based on geochemical and hydrogeology
[摘要] The research area has two geothermal system's prospect, ie Gede-Pangrango and Pancar that covering Cianjur, Sukabumi, and Bogor, West Java. Determination of geothermal system's conceptual model and recharge area are purpose of this research. The main data are stable isotope 18O and 2H from cold springs and river water, also secondary data as complement. Gede-Pangrango geothermal system has two hot springs, chloride-sulfate water (51°C) and chloride-bicarbonate water (40°C). Solfatar (167°C) and fumarole (70°C) are at the Mt. Gede's peak. It's parent fluid has temperature (tNa-K)=275-295°C. Pancar geothermal system has two hot springs, sulfate water (54°C) and chloride-sulfate (66°C). It's parent fluid has temperature (tNa-K)=190-210°C. Based on geophysical data, the reservoir rock of Gede-Pangrango is in volcanic rock, at elevation 250 to -500 m and Pancar is in sedimentary rock, at elevation alteration -1000 to -1750m. Whereas the cap rock is in alteration rock of volcanic and sedimentry. The 18O and 2H isotope analysis shows the recharge area of Gede-Pangrango and Pancar geothermal system at elevation 1100-1156.8 m and 853.5 - 899.12 m plus latitude 9263000-9263500 mS and 9265300-9265800 mS.
[发布日期]  [发布机构] Geological Engineering, Institut Teknologi Bandung, Jl Ganesha 10, West Java, Bandung; 40132, Indonesia^1
[效力级别] 矿业工程 [学科分类] 
[关键词] Conceptual model;Geophysical data;Geothermal systems;Isotope analysis;Recharge area;Reservoir rock;Secondary datum;Stable isotopes [时效性] 
   浏览次数:34      统一登录查看全文      激活码登录查看全文