已收录 268921 条政策
 政策提纲
  • 暂无提纲
Influence Factors Analysis of Ultrasonic Detection Gravel Terrain Elevation Precision Based on Orthogonal Experiment
[摘要] In the depth control system of clean-up collect mechanical, the influence factors of ultrasonic detection accuracy such as sensor frequency, installation height, marching speed and earth's surface roughness are analysed by orthogonal experiment through range and variance analysis methods. The results show that installation angle and marching speed are the most important influencing factors, the installation height and surface roughness have no significant effect. In the practical application, the installation angle and marching speed should be considered firstly, the sensor frequency and installation height can be adjusted according to the terrain.
[发布日期]  [发布机构] Northwest Institute of Nuclear Technology, Xi'an; 710024, China^1
[效力级别] 计算机科学 [学科分类] 
[关键词] Depth control system;Factors analysis;Installation angle;Installation heights;Orthogonal experiment;Terrain elevation;Ultrasonic detection;Variance analysis methods [时效性] 
   浏览次数:58      统一登录查看全文      激活码登录查看全文