Comparison Study of Different BOD Tests in the Determination of BOD7Evaluated in a Model Domestic Sewage
[摘要] The aim of this research was to study the suitability of a manometric respirometric test (OECD 301F) for the determination of biological oxygen demand (BOD) in domestic wastewater. This was done by comparing four different BOD tests (a manometric respirometric test, oxygen sensor determination, iodometric titration, and UV absorption measurement) and by evaluating the BOD7value after a short-term measurement applying the manometric respirometric test. Measurements were done in three dif-ferent laboratories. The respirometric test was performed well on municipal sewage, and the precision of results was good. There were minor deviations between BOD7values as determined by the different methods, but the deviations were not essentially bigenough to have a practical impact. Evaluation of the BOD7value after two or three days' incubation by the respirometric method was shown to work well; average deviations between measured and evaluated values after three days' incubation were 5–18%. Hence, the manometric respirometric test proved to be a rapid and suitable tool for process control purposes.
[发布日期] [发布机构]
[效力级别] [学科分类] 分析化学
[关键词] [时效性]