The Effect of Minimum Distance Between Bamboo Strengtheners on Flexural Strength of Bamboo Reinforced Cement
[摘要] Various species of Bamboo is widely available in Indonesia. Usually it is used as pillars, roof frame, and for walls in a woven form and it can be used for steel substitute in reinforced concrete. In making bamboo as a strengtheners or reinforcement a proper volume fraction should be chosen. Besides that, the minimum distance between bamboo bars or inter-strengtheners distance must be determined so that the reinforcement effect on cement matrix takes place. Ten variations of mixtures were used in this research. The number and distance between reinforce bars and its arrangement perpendicular or parallel with loading direction. From the observation it is found that both of the vertically and horizontally arranged bamboo bars at minimum inter-strengtheners distance of 10 mm gave maximum reinforcement and the flexural strength are 16.1 ± 0.3 MPa and 15.8 ± 0.6 MPa. Whereas cement only sample gave 7.2 ± 0.6 MPa hence 2 folds increase. For distance less than 10 mm, the flexural strength is lower, even volume fraction is relatively high and it supposed to give higher strength, in fact this is due to composite reinforcement effect did not occur and this is belief due to a hindered hydration process.
[发布日期] [发布机构] Department of Materials Engineering, Faculty of Mechanical and Aerospace Engineering, Bandung Institute of Technology, Ganesha 10, Bandung; 40132, Indonesia^1
[效力级别] 金属学 [学科分类] 材料科学(综合)
[关键词] Cement matrix;Composite reinforcement;Hydration process;Loading direction;Minimum distance;minimum inter-strengthener distance;Reinforcement effects;Roof frames [时效性]