Incinerator Flue Gas Cleaning Using Wet-Type Electrostatic Precipitator
[摘要] References(11)Cited-By(5)An experimental approach has been adopted to remove dioxins and other pollutants from incinerator flue gas in a pilot-scale experimental system. The main objective of this study is to investigate the combined system for simultaneous removal of gaseous pollutants and dusts. The combined gas cleaning system consists of a radiator, a scrubber and a wet-type electrostatic precipitator (ESP). Dioxins can be decomposed effectively using after-burners downstream of the incinerator by maintaining the gas temperature around 850 ± 20°C. Fractional removal rates for various kinds of dioxins (PCDDs + PCDFs) were measured in this study. When the combined system is used, dioxin removal rates of 90–92% are achieved over a wide range of initial concentrations of dioxins. The combined system is also found to be effective in the removal of NOx, SOx, HCl, and dust.
[发布日期] [发布机构]
[效力级别] [学科分类]
[关键词] Dioxins;Corona Discharge;Incineration;Flue Gas Cleaning;Wet-Type Electrostatic Precipitator [时效性]