Study on Degradation Rate Constant of Chlorobenzene in Aqueous Solution Using a Recycle Ultrasonic Reactor
[摘要] References(15)Cited-By(8)Degradation of chlorobenzene in aqueous solution using a recycle ultrasonic reactor was investigated. The degradation rate constant increased with increasing volumetric flow rates, reactor volumes and frequencies with electric power kept constant. Effective ultrasonic intensity was measured by a simple chemical dosimetry based on observation of the fading-time of alkaline phenolphthalein solution. The rate constant of the degradation reaction of chlorobenzene was proportional to the ultrasonic intensity Dult [J/g], that is, a measure of the sonochemical effects. These results indicate that sonochemical effects can be interpreted in terms of the ultrasonic intensity or the ultrasonic energy consumed in the reactor.
[发布日期] [发布机构]
[效力级别] [学科分类]
[关键词] Chlorobenzene;Recycle Ultrasonic Reactor;Volumetric Flow Rate;Reactor Volume;Ultrasonic Intensity [时效性]