Simultaneous spectrophotometric determination of paracetamol and ibuprofen in pharmaceutical formulations by multivariate calibration
[摘要] A simple method was proposed for determination of paracetamol and ibuprofen in tablets, based on UV measurements and partial least squares. The procedure was performed at pH 10.5, in the concentration ranges 3.00-15.00 µg ml-1 (paracetamol) and 2.40-12.00 µg ml-1 (ibuprofen). The model was able to predict paracetamol and ibuprofen in synthetic mixtures with root mean squares errors of prediction of 0.12 and 0.17 µg ml-1, respectively. Figures of merit (sensitivity, limit of detection and precision) were also estimated. The results achieved for the determination of these drugs in pharmaceutical formulations were in agreement with label claims and verified by HPLC.
[发布日期] [发布机构]
[效力级别] [学科分类] 化学(综合)
[关键词] PLS;quality control;acetaminophen. [时效性]