Tokamak Plasmas : Internal magnetic field measurement in tokamak plasmas using a Zeeman polarimeter
[摘要] In a tokamak plasma, the poloidal magnetic field profile closely depends on the current density profile. We can deduce the internal magnetic field from the analysis of circular polarization of the spectral lines emitted by the plasma. The theory of the measurement and a detailed design of the Zeeman polarimeter constructed to measure the poloidal field profile in the ADITYA tokamak are presented. The Fabry-Perot which we have employed in our design, with photodiode arrays followed by lock-in detection of the polarization signal, allows the measurement of the fractional circular polarization. In this system He-II line with wavelength 4686 Ã… is adopted as the monitoring spectral line. The line emission used in the present measurement is not well localized in the plasma, necessiating the use of a spatial inversion procedure to obtain the local values of the field.
[发布日期]  [发布机构] 
[效力级别]  [学科分类] 物理(综合)
[关键词] Tokamak;polarimeter;Zeeman effect [时效性] 
   浏览次数:43      统一登录查看全文      激活码登录查看全文