Standardization of Incubation Time and Temperature for Eight Radioimmunoassays
[摘要] We wanted to know if incubation time and temperature for many radioimmunoassay methods could be standardized, to decrease assay time and so improve efficiency. Percentage binding was determined for triiodothyronine, thyroxine, digoxin, digitoxin, testosterone, aldosterone, estradiol, and diphenylhydantoin when the reaction mixtures were incubated at 6-8, 22, or 37 °C for various periods of time. In all methods tested, binding of antigen to antibody was greatest when the reaction mixtures were incubated at 6-8 °C, less at 22 °C, and least at 37 °C. Maximum binding occurred within 30-60 min at each temperature for all methods tested. Hence, it is possible to standardize the incubation time and temperature for these eight radioimmunoassay methods to 60 min at 6-8 °C.
[发布日期] [发布机构]
[效力级别] [学科分类] 过敏症与临床免疫学
[关键词] [时效性]