Flexural Response of CFRP Prestressed Concrete Box Beams for Highway Bridges
[摘要]

This paper presents an experimental and analytical investigation of the flexural response of box beams reinforced and prestressed using carbon fiber reinforced polymer (CFRP) tendons. Two one-third scale box beams were prestressed using seven bonded pretensioning tendons and six unbonded post-tensioning tendons. A third beam was prestressed with seven bonded pretensioning tendons and six  non-prestressed unbonded posttensioning tendons. Beams were reinforced with carbon fiber composite cable stirrups and tested to failure. A computer program was developed to predict deflection, strain,  and post-tensioning forces at various loads. A parametric analysis examined the effects of the level of pretensioning  and post-tensioning forces on the overall flexural response. Results showed that  the beam prestressed using both pretensioning and unbonded post-tensioning tendons had a 26 percent higher ultimate load capacity and 36 percent lower energy ratio than the beam with  non-prestressed unbonded post-tensioning tendons. Levels of initial pretensioning and posttensioning forces significantly affect the flexural response and beam failure mode.

[发布日期]  [发布机构] 
[效力级别]  [学科分类] 建筑学
[关键词]  [时效性] 