已收录 268921 条政策
 政策提纲
  • 暂无提纲
High-strength self-consolidating concrete girders subjected to elevated compressive fiber stresses, part 1: Prestress loss and camber behavior
[摘要]

The design of prestressed concrete members is restricted by the requirement that the extreme compressive fiber stress at midspan of simply supported members be less than 60% of the concrete compressive strength at release of prestressing. The purported purpose of this limit is to address serviceability performance, but it places unnecessary limits on the capability of the materials. For this research program, six prestressed concretegirders were produced with high-strength self-consolidating concrete and subjected to compressive fiber stress levels ranging from 65% to 84% of the concrete compressive strength at release of prestressing. Time-dependent concrete surface strains were measured using a mechanical strain gauge, with a focus on measuring drying creep and determining its relationship to prestress losses. This research demonstrates that current American Association of State Highway and Transportation Officials load and resistance factor design prestress-loss prediction methods developed for high-strength concrete overestimate losses by 18%, whereas older methods for prestress losses developed for normal-strength concrete produced more-accurate results. Based on these results and work performed by others, the authors concur with increasing the allowable compressive stress limit at any location to 70% of the concrete compressive strength at release of prestressing.

[发布日期]  [发布机构] 
[效力级别]  [学科分类] 建筑学
[关键词]  [时效性] 
   浏览次数:5      统一登录查看全文      激活码登录查看全文