Performance of FRP Tendon-Anchor Systems for Prestressed Concrete Structures
[摘要]

Considerable research has already been conducted on the mechanical response of fiber reinforced plastic (FRP) tendons for use in pretensioning and post-tensioning concrete structures. This research has  been performed primarily outside of the United States and directly by tendon manufacturers. An experimental investigation was undertaken to provide a domestic evaluation of the mechanical  performance of ten different aramid, glass, and carbon FRP tendons, with attention paid to the effects of the anchorage device recommended by the manufacturer. The first phase of the project herein  reported consisted of the verification of some tendonspecific properties, namely: ultimate strength, modulus of elasticity, and ultimate strain. It was determined that, given the limitation of the  experimental program, a reasonable correlation exists with data supplied by manufacturers. In most cases, the anchorage devices permitted the tensioning to failure of the FRP tendons. Ultimate load  capacity was generally controlled by the anchor rather than the tendon itself, suggesting that anchor efficiency could be improved. It was  determined that heating one anchor to 60°C (140°F) had no detrimental effect on the  tensile performance of the tendon-anchor system.

[发布日期]  [发布机构] 
[效力级别]  [学科分类] 建筑学
[关键词]  [时效性] 