已收录 268921 条政策
 政策提纲
  • 暂无提纲
Load Testing of Transversely Prestressed Double Tee Bridges
[摘要]

Discusses the testing procedure and strength evaluation of two identical double tee prestressed concrete bridges owned by the City of Tallahassee, Florida. The various elements of each bridge were  examined by placing strain or deflection transducers at critical locations along the elements. The bridge was then incrementally loaded to induce maximum stress-strain effects. The data collected from the  various instruments were used to establish the strength of each component and also to determine the load distribution in the structure. The load testing procedure, data acquisition, analytical model, and  comparison of experimental data to analytical results are presented.

[发布日期]  [发布机构] 
[效力级别]  [学科分类] 建筑学
[关键词]  [时效性] 
   浏览次数:3      统一登录查看全文      激活码登录查看全文