Changes in Blood Viscosity With Synthetic Protease Inhibitors
[摘要] References(15)Cited-By(4)We examined the effects on whole blood viscosity and coagulation time of various dosages of the synthetic low-molecular protease inhibitors gabexate mesilate and nafamostat mesilate with an oscillation-type viscometer. When either agent was added, blood viscosity decreased dose-dependently along a sigmoid-like curve. Furthermore, coagulation time was shorter with gabexate mesilate than with nafamostat mesilate owing to the differences of half-life in human blood. Thrombin generation, which results from the activation of coagulation factors, is inhibited by synthetic protease inhibitors and subsequently decreases blood viscosity dose-dependently.
[发布日期] [发布机构]
[效力级别] [学科分类] 药学
[关键词] blood viscosity;synthetic protease inhibitor;rheology [时效性]