Microdosimetric studies of Auger electrons from DNA-incorporated 123-I using the micronucleus assay and the Geant4 Monte Carlo simulation tookit
[摘要] ENGLISH ABSTRACT: This study's focus is on the determination and quantization of radiation damage on a cellular level due to the decay of the Auger electron-emitting 123I and the replication of this energy deposition using Geant4 Monte Carlo simulations. The relatively short half-life of 123I (13.2 hours) makes it ideal for studies of Auger electrons which induce biological damage similar to that of high linear energy transfer radiations, when permitted to deposit their energy in close proximity to DNA. Due to small cellular dimensions, direct dose measurements are impossible but estimates may be made from Monte Carlo simulations. In this investigation the thymidine analogue 5-[123I]-iodo-2-deoxyuridine (123IUdR) was used to incorporate the 123I into the cellular DNA of T-lymphocytes from two human donors. Radiation induced micronuclei were numerated in binucleated cells using fluorescence microscopy. The energy deposition per decay of 123I was calculated within a spherical geometry, having the same size and density as a human lymphocyte, using the open source Geant4 toolkit. The absorbed energy per disintegration was used to convert the incorporated 123I activity (Bq) into absorbed dose (Gy) values, in order to compare the biological damage caused by the radioactive iodine to 60Co γ-radiation. A linear relationship between micronuclei frequency and 123I activity could be established. The linear dose-response noted for Auger electrons in the study is indicative of the high-LET nature of these particles. Using the linear-quadratic dose-response curve for micronuclei frequencies following exposure to graded doses of 60Co γ-rays, the relative biological effectiveness (RBE) of the DNA incorporated 123I estimated in this work was found to range from 19 ± 10 to 32 ± 7 for lymphocyte donor 1 and 15 ± 6 to 42 ± 11 for donor 2. The dose limiting RBE (RBEM) for lymphocyte donor 1 and 2 are respectively 34 ± 8 and 50 ± 15 and follows the expected shift in terms of the inherent radiosensitivity of the donors. We also considered the inclusion of the S-phase fraction of the lymphocytes in the dosimetry calculations. The resultant RBEs of the dose points of lymphocyte donor 1 ranges from 4 ± 2 to 7 ± 2, and those of donor 2 ranges from 3 ± 1 to 9 ± 2. The RBEM for lymphocyte donor 1 and 2 are respectively 7 ± 2 and 11 ± 3. The inclusion of the S-phase fraction reduces the calculated RBEs significantly and these observed RBE values relate well to those obtained in studies with fibroblasts and 125IUdR.
[发布日期] [发布机构] Stellenbosch University
[效力级别] [学科分类]
[关键词] [时效性]