Optimal Cutoff Value of Serum Adenosine Deaminase Activity for Diagnosing Acute Scrub Typhus
[摘要] References(13)The objective of this study was to determine the optimal cutoff value of serum adenosine deaminase (ADA) activity for diagnosing scrub typhus in acute febrile patients, especially in the autumn. A total of 715 febrile patients were included; 286 of them were diagnosed with acute scrub typhus. The mean serum ADA activities in patients with and without scrub typhus were 42.8 ± 13.4 IU/L and 17.2 ± 11.5 IU/L, respectively. The optimal cutoff value for serum ADA activity was determined to be 25.0 IU/L with a sensitivity of 92.3%, specificity of 86.6%, and area under the curve of 89.4% using a receiver-operating characteristic curve analysis. The possibility of scrub typhus must be considered when acute febrile patients present with high ADA activity (>25 IU/L), especially in the autumn. Determining the optimal serum ADA activity cutoff value may help clinicians diagnose acute scrub typhus prior to serological confirmation.
[发布日期]  [发布机构] 
[效力级别]  [学科分类] 传染病学
[关键词] scrub typhus;adenosine deaminase [时效性] 
   浏览次数:4      统一登录查看全文      激活码登录查看全文