已收录 268921 条政策
 政策提纲
  • 暂无提纲
Pollutants Removal from Synthetic Wastewater by the Combined Electrochemical Sequencing Batch Reactor
[摘要] Synthetic domestic wastewater was treated via combining treatment methods, including electrochemical oxidation, adsorption, and sequencing batch reactor (SBR). In the upper part of the reactor, an anode and a cathode (Ti/RuO2-IrO2) were organized in parallel for the electrochemical oxidation procedure. Sodium sulfate (Na2SO4) with a concentration of 2.5 g/L was applied as the electrolyte. The voltage and current were fixed on 7.50 V and 0.40 A, respectively. Then, 15% working value of the reactor was filled by activated sludge, and 85% working value of the reactor was added with synthetic wastewater. Powdered cockleshell, 1.5 g/L, was added in the reactor to do ion-exchange. Response surface methodology was employed for statistical analysis. Reaction time (h) and pH were considered as independent factors. A total of 97.0% biochemical oxygen demand, 99.9% phosphorous and 88.6% cadmium were eliminated at the optimum reaction time (80.0 min) and pH (6.4).
[发布日期]  [发布机构] 
[效力级别]  [学科分类] 计算机应用
[关键词] Adsorption;electrochemical oxidation;metals;sequencing batch reactor. [时效性] 
   浏览次数:11      统一登录查看全文      激活码登录查看全文