Current profile measurements using MSE on Alcator C-Mod
[摘要] (cont.) The spurious drift in the measurement has been identified as the thermals tress induced birefringence imposed on the in-vessel lenses. By modeling this effect as a single wave plate, an in-situ calibration method has been proposed and its feasibility was experimentally verified. Based on the experiments that characterized the thermal response of the system, a single-layer heat shield with gold plating and a lens holder which reduces the thermal conduction path to the lens have been designed and fabricated. A more rigorous model that includes an intrinsic phase shift by mirrors reveals the thermal phase shift can be greatly magnified by the intrinsic phase shift. The current density profiles from LHCD experiments have been obtained from the MSE data corrected by a baseline magnetic equilibrium whose internal profile is constrained by the sawtooth inversion radius. The resultant profiles successfully demonstrate several standard predictions of LHCD theory such as the dependence of efficiency on the parallel refractive index and the off-axis current drive.
[发布日期] [发布机构] Massachusetts Institute of Technology
[效力级别] [学科分类]
[关键词] [时效性]