Intraoperative spinal cord monitoring during the surgical correction of scoliosis due to cerebral palsy and other neuromuscular disorders
[摘要] PurposePatients with neuromuscular scoliosis are at increased risk of neurological deficit post-operatively, but are a difficult population on whom to perform neurophysiological monitoring. We look here at a 7-year sample of our practice in the monitoring of neuromuscular patients.MethodsA retrospective chart review was performed for 109 patients who underwent correction of neuromuscular scoliosis within our institution between 2005 and 2011.ResultsOf 109 patients who were identified, intraoperative monitoring was attempted in 66 cases. In eight cases (13 %), no reliable monitoring could be achieved and was therefore abandoned. On nine occasions, there was a significant drop in at least one modality intraoperatively. None of these nine suffered any clinically observable neurological deficit post-operatively. Of the 109 patients, 2 had clinically detectable deficits post-operatively, both of whom had undergone normal intraoperative monitoring.ConclusionsThe two patients with observable deficit had their instrumentation left in situ after discussion with them and/or parents. Spinal cord monitoring in this population is possible but potentially unreliable. Surgeons will need to carefully consider the use of monitoring in their management of this challenging population...
[发布日期]  [发布机构] 
[效力级别]  [学科分类] 骨科学
[关键词] Neuromuscular ;Scoliosis ;Intraoperative ;Neurophysiological ;Monitoring ;Spinal  [时效性] 
   浏览次数:3      统一登录查看全文      激活码登录查看全文